null

Skip to end of banner
Go to start of banner

MSC Basic Settings

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Version History

« Previous Version 9 Next »

In this customizing step, basic MSC settings are made.

Parameter

Parameter description

Mat.view trans.

Definition of the transaction in order to display a material master record directly from the object view (search or structure). Without entry, transaction MM03 will be used.

Doc.disp.trans.

Definition of the transaction in order to display a document info record directly from the object display (search or structure). Without entry, transaction CV03N will be used.

Format document key

Document key definition in the display of the MSC main dialogue. The following key words (capital letters only) will be translated.

·    <DOKAR>      Document type

·    <DOKNR>      Document number

·    <DOKTL>       Part document number

·    <DOKVR>      Version

All other text will not be translated and output.

Orig.control char.

Definition of a character, which will allow overriding the default behaviour for the handling of originals. If the character is not assigned or not existing for the document info record, the handling will be act. to the standard.

The following values must be allowed in the character definition:

  • " "       Default behaviour

  • "C“     Copy original (clone)

  • "D“     Don't copy original / ignore

  • "T“      Don't copy original / template

In general the handling of document originals is according the settings in Clone; Settings/Copy .

ProConfiguration  Doc. Control

If BOM are cloned and the material master records have ProConfiguration relevant documents assigned, the objects are controlled in general by ProConfiguration processing scenarios (see also Clone; Settings/Copy).

If a characteristic is set and assigned to a document info record, the ProConfiguration  processing scenario will be overrode for this document.

The following values must be allowed in the character definition:

  • " "       Default behaviour (Process.Scen.)

  • "C“     Always new DIR without reference

  • "R“     Link (if allowed)

  • "D“     Ignore document

The following rules will be applied:

  • If option „D“ is set and the relevant object in the ProConfiguration  is not optional, option „C“ will be used

  • If option „R“ is used and the document cannot be linked (cannot be used multiply), the option will be ignored.

LED-Ikonen

Status actions (Default values, see Definition Mass Operations

Status

Ikone – Option nicht gesetzt

Ikone – Option gesetzt

Status OK

ICON_GREEN_LIGHT

ICON_LED_GREEN

Change possible

ICON_YELLOW_LIGHT

ICON_LED_YELLOW

Not possible

ICON_RED_LIGHT

ICON_LED_RED

View extensions

Status

Ikone – Option nicht gesetzt

Ikone – Option gesetzt

View already existing

ICON_STATUS_BOOKED

ICON_LED_GREEN

At least one view must be created

ICON_STATUS_OPEN

ICON_LED_RED

BOM already existing

ICON_TREE

ICON_LED_GREEN

BOM must be created

ICON_BOM

ICON_LED_RED

  • No labels