Attributes to CAD integration

Attributes to CAD integration

Attribute

CAD integration

Description

Attribute

CAD integration

Description

ATTFRMT

DSC NX

The format in which the DSC NX document attributes should be written:

  • ECTR3: Attributes in the DRAW RES fields.

  • ECTR4: Attributes in the CDESK_DRAW fields
    For details, see the corresponding DSC documentation.

DOCVS_KEEP_ATTRIB

All

Allows individual attributes of CAD types to be set in accordance with the previous version when documents are versioned and not formatted again.
This is specifically required for DSC NX (UGDSC), where the CAD type attribute "UGS" must be set according to the previous version when a new version is created, as this attribute may be changed. The following entry must be made accordingly. In this example, the DTYPE attribute should also be transferred.

Several attributes are to be entered separately with ";".

DUGDSCFLDR

DSC NX

In the DSC object manager, the user is shown his worklist from his personal folder. This folder consists of one class and the content is the material masters assigned to this class.
ProIntegrationLib can automatically assign this class to a new material master if NX objects are also created for it. The class must be specified for this purpose.
The name of the class is usually the SAP user name followed by "_NS". Enter <UNAME> as a placeholder for the SAP user name:

If the class does not belong to class type 001, enter the class type you want to use with / separately before the class:

MSCUGNEW

DSC NX

This attribute activates the clone functionality new with V1.2.0, which can display NX structures completely in ProMassOperations and supports the call of RenameRepair.

DUGMSCCLON

DSC NX

ProNovia internal use only. If the new cloning functionality is used with ProMassOperations (see attribute MSCUGNEW), the following program must be entered here: /PRONOVIA/DUG_MSC_CLONE_NEW

STUSEECM

All

In general, structures (BOMs) are created between CAD documents without reference to engineering change management. If you maintain this attribute for a CAD integration with value "X", the CAD structures are also created and maintained with reference to Engineering Change Management.

RRCONVLOC

DSC NX

Converter Location for RenameRepair.

RRSTATPLND

DSC NX

Document status that is set by the plug-in before RenameRepair is called.

RRSTATWORK

DSC NX

Working status of RenameRepair.

RRSTATERR

DSC NX

Document status in case of RenameRepair error.

RRSTATOK

DSC NX

Document status when RenameRepair has been carried out successfully. If this attribute is not filled, each document is reset to its original status before RenameRepair is called.

RRVERSION

DSC NX

Current version of the RenameRepair server (for example, 2.1). The version is required to check whether certain functions are already supported by the RR server (for example, WAVECOPY from RR V2.1).