Missing updates of redundantly stored reference characteristic

Missing updates of redundantly stored reference characteristic

The values of object characteristics (or persistent reference characteristics) do not match the object data fields.

  • SAP Note 2965267 (Keep redundantly stored object characteristic data synchronized with the main object) must be implemented.

  • SAP Note 2967500 (Keep material data of object characteristics synchronized with the classification table) must be implemented for the material.

  • Product support has been added with UTI V9.22.0, CFM 8.3.3, ADM V4.6.2.

  • The migration of the classification data must have been carried out for the SAP notes and product adjustments to work. The migration can be carried out with the program RNGC_XPRA_01_DATUB_KSSK.

  • The incorrect characteristics can be corrected using the ProNovia program /PRONOVIA/UPDATE_REF_CHAR_VAL.